Product Description:

Model /Specification

S-25-5

S-25-12

S-25-15

S-25-24

DC output voltage

5V

7.5V

12V

24V

Output voltage error (Note2)

±2%

±1%

±1%

±1%

Rated output current

5A

18A

12A

6A

Output current rage

0-5A

0-2.1A

0-1.7A

0-1.1A

Wave and noise(Note3)

50mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.3%

±0.2%

Load stability(Note5)

±1%

±0.5%

±0.3%

±0.2%

DC output power

25W

25.2W

25.5W

26.4W

Efficiency

72%/115VAC

76%/115VAC

77%/115VAC

80%/115VAC

Adjustable range for DC voltage

+10,-5%

±10%

±10%

±10%

AC input voltage range

85264VAC/4763VAC;120370VDC

Input current

0.6A/115V 0.35A/230V

AC impulse current

Cold-start current 15A/115V 30A/230V

Leakage current

<0.75mA/240VAC

Overload protection

105%150% TypePULSING HICCUP SHUTDOWN;  Reset; auto recovery

Over-voltage protection

115%135%

High-temperature protection

……

Temperature coefficient

±0.03%(050)

Setup rise hold up time

800ms,50ms,20ms/115VAC 300ms,50ms,80ms/230VAC

Vibration

10500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval3KVACInput and enclosure1.5KVACOutput and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure0500VAC/100M Ohms

Working temperature and humidity

-10+6020%90%RH

Store temperature and humidity

-20+85,10%95RH

Overall dimension

99*97*35mm

Weight

0.37Kgs

Safety standards

Meet UL1012,TUV EN60950

EMC standards

Meet IEC801-2,3,4,IEC555-2

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test:The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.