You are here: Home >> Industries & Products >> Switching Power Supply >> S series >> S-1000 Switching Power Supply
86-577-61989999 86-577-61891122 cncele@cncele.com cncelegroup@hotmail.com CNC.ELE.GROUP
S-1000 Switching Power Supply
S-1000 Switching Power Supply
bookmark this page Bookmark This Page
live messenger Live Messenger
skype me Skype Me
e-mail us cncele@cncele.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download


 

Product Description: 

Model / Specification

SP-1000-12

SP-1000-13.5

SP-1000-15

SP-1000-24

SP-1000-27

SP-1000-48

DC output voltage

12V

13.5V

15V

24V

27V

48V

Output voltage error

±1%

±1%

±1%

±1%

±1%

±1%

Rated output current

50A

44A

40A

25A

22A

12.5A

Output current rage

0-50A

0-44A

0-40A

0-25A

0-22A

0-12.5A

Wave and noise

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

Inlet stability

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note5)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

DC output power

600W

600W

600W

600W

600W

600W

Efficiency

83%

84%

84%

85.5%

86.5%

87%

Adjustable range for DC voltage

10-13.2V

12-15V

13.5-18V

20-26.4V

24-30V

41-56V

AC input voltage range

90~132AC/180~264AC

AC Input current

12A/115V 7.5A/230VAC

AC impulse current

25A/115V 50A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%135% TypePULSING HICCUP SHUTDOWN Reset: auto recovery

Over-voltage protection

.........

 

 

 

 

 

Temperature coefficient

...........

Setup rise hold up time

±0.03%(0~50)

Vibration

10500Hz, 2G 10min./1cycle,Period for 60min,EACH AXES

Withstand voltage

Input and output interval1.5KvAC,Input and enclosure1.5KVAC Output and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure500VDC/100M Ohms

Working temperature and humidity

-10+50,20%90%RH

Store temperature and humidity

-20+85,10%95%%RH

Overall dimension

247 x 147 x 63.5mm

Weight

2.1Kgs

Safety standards

Meet UL 1950 requirement (NOT apply for the mark)

EMC standards

CISPR22(EN55022)IEC1000-4,2,3,4,5,6,8,11 IEC100-3-2

Note:1.The testing condition for the parameter above is:230VAC input,  rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.

SendMessage