You are here: Home >> Industries & Products >> Switching Power Supply >> NE series >> NES-200 Switching Power Supply
86-577-61989999 86-577-61891122 cncele@cncele.com cncelegroup@hotmail.com CNC.ELE.GROUP
NES-200 Switching Power Supply
NES-200 Switching Power Supply
bookmark this page Bookmark This Page
live messenger Live Messenger
skype me Skype Me
e-mail us cncele@cncele.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download


 

Model

 

NES-200-3.3

NES-200-5

NES-200-7.5

NES-200-12

NES-200-15

NES-200-24

NES-200-27

NES-200-36

NES-150-48

Output

DC output voltage

3.3V

5V

7.5V

12V

15V

24V

27V

36V

48V

Rated output current

40A

40A

27A

17A

14A

8.8A

7.8A

5.9A

4.4A

Output current range

0-40A

0-40A

0-27A

0-17A

0-14A

0-8.8A

0-7.8A

0-5.9A

0-4.4A

Rated output power

132W

200W

202.5W

204W

210W

211.2W

210.6W

212.4W

211.2W

Wave and noise

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

240mVp-p

240mVp-p

Voltage adjustment range

2.97-3.7V

4.5-5.6V

6-9V

10-13.5V

13.5-18V

20-26.4V

26-32V

32-40V

41-56V

Voltage accuracy

±2.0%

±2.0%

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Linear adjust rate

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Over-load adjust rate

±1.5%

±1.0%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Set up, rise time

1000ms,50ms/230VAC 1000ms,50ms/115VAC(full load)

Hold up time

20ms/230VAC 16ms/115VAC (full load)

Input

Input voltage range

90-132VAC or 254-370VAC Or 180-264VAC

Frequency range

47-63Hz

Efficiency

75%

79%

82%

85%

85%

87%

88%

89%

89%

AC current

4.5A/115VAC 2.5A/230VAC

Inrush current

40A/115VAC 55A/230VAC

Leakage current

3.5mA/240VAC

Protection

 

Overload protection

Rated output power 105%150% set overload protection

Protection typepulsing hiccupshut down abnormal condition. auto recovery

Over-voltage protection

3.8-4.9V

5.75-6.75V

9.4-10.9v

13.8-16.2V

18-21V

27.6-32.4V

33.7-39.2V

41.4-46.8v

57.6-67.2

Protection typeCut off output. auto recovery

Condition

 

Working temperature

-20+50 (Reference derating curve)

Working humidity

2090RH (No Condensation)

Store temperature and humidity

-40+85;10%95%RH

Temperature factor

±0.03%/0-45

shock resistance

10500Hz3G 10min./1cycleperiod for 60 minXYZ axes

 

Safety and electromagnetic compatibility

 

Safety standard

UL60950-1,CB(EN60950)-1, pass GB4943

Withstand voltage

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC 70%RH

Electromagnetic interference

EN55022(CISPR22) Class B, GB9254 ClassB

Harmonic current

EN61000-3-2,-3

Electronmagnetic stamina

EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-1

Others

MTBF

≥271.9Khrs, MIL-HDBK-217F(25)

Measurement

215*115*50mm(L*W*H)

Packing

0.93k.g12pcs,12k.g/0.92CUFT

Notes

1. The testing condition for the parameter above is:230VAC input, rated load,25.
2. Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting 
3. Error,include the setting error, current regulation and voltage regulation

SendMessage