Specification:

Model

NED-100A

NED-100B

NED-100C

NED-100D

Output

Output channel

CH1

CH2

CH1

CH2

CH1

CH2

CH1

CH2

DC output voltage

5V

12V

5V

24V

12V

5V

24V

5V

Rated output current

10A

4.2A

8A

2.5A

7A

3A

3.5A

3A

Output current range

2-10A

0.7-7.0A

1-10A

0.3-3.5

0-8A

0-3A

0-4A

0-3A

Rated output power

100.4W

100W

99W

99W

Wave and noise

80mVp-p

120mVp-p

80mVp-p

200mVp-p

120mVp-p

80mVp-p

120mVp-p

80mVp-p

Voltage adjustment range

CH1:4.75-5.5V

CH1:4.75-5.5V

CH1:11.4-13.2V

CH1:22.8-26.4V

Voltage accuracy

±2.0%

±1.0%

±2.0%

±8.0%

±2.0%

±3.0%

±2.0%

±3.0%

Linear adjust rate

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Over-load adjust rate

±1.0%

±5.0%

±1.0%

±4%

±1.0%

±2.0%

±1.0%

±2.0%

Set up, rise time

2000ms,30ms/230VAC 1200ms,30ms/115VAC(full load)

Hold up time

25ms/230VAC 20ms/115VAC (full load)

Input

Input voltage range

88-132/176-264VAC or 248-373VAC

Frequency range

47-63Hz

Efficiency

80%

82%

80%

82%

AC current

2A/115VAC 1.2A/230VAC

Inrush current

Cold-start 45A

Leakage current

2mA/240VAC

Protection

 

Overload protection

Rated output power 110%150% set overload protection

Protection typepulsing hiccupshut down voltage abnormal condition. auto recovery

Over-voltage protection

CHI:5.75-6.75V

CHI:5.75-6.75V

CHI:13.8-15.8V

CHI:27.6-32.4V

Protection typepulsing hiccupshut down abnormal condition. auto recovery

Condition

 

Working temperature

-20+60 (Reference derating curve)

Working humidity

2090RH (No Condensation)

Store temperature and humidity

-40+85;10%95%RH

Temperature factor

±0.03%/0-45

shock resistance

10500Hz2G 10min./1cycleperiod for 60 minXYZ axes

Safety and electromagnetic compatibility

 

Safety standard

UL60950-1,CB(EN60950)-1

Withstand voltage

I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC

Electromagnetic interference

EN55022(CISPR22) Class B

Harmonic current

EN61000-3-2,-3

Electronmagnetic stamina

EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-1

Others

MTBF

≥320.7Khrs, MIL-HDBK-217F(25)

Measurement

199*98*38mm(L*W*H)

Packing

0.55k.g30pcs17.5k.g/0.97CUFT

Notes

1. The testing condition for the parameter above is:230VAC input, rated load,25
2. Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
3. Error,include the setting error, current regulation and voltage regulation 
4.Linear adjust rate test method: under rated over-load, From low voltage to high voltage 
5.Over-load adjustment rate test method: from 20%-100% rated over-load , others output under 60% .
6.In current range, total power≤ reserve power
7.Inner components include power supply, Combined with the electromagnetic compatibility test