You are here: Home >> Industries & Products >> Switching Power Supply >> Din Rail Series >> DR-45 Switching Power Supply
86-577-61989999 86-577-61891122 cncele@cncele.com cncelegroup@hotmail.com CNC.ELE.GROUP
DR-45 Switching Power Supply
DR-45 Switching Power Supply
bookmark this page Bookmark This Page
live messenger Live Messenger
skype me Skype Me
e-mail us cncele@cncele.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download


 

Product Description: 

Model / Specification

DR-45-5

DR-45-12

DR-45-15

DR-45-24

DC output voltage

5V

12V

15V

24V

Output voltage error (Note2)

±2%

±1%

±1%

±1%

Rated output current

5A

3.5A

2.8A

2A

Output current rage

0-5A

0-3.5A

0-2.8A

0-2A

Wave and noise(Note3)

100mVp-p

200mVp-p

240mVp-p

480mVp-p

Inlet stability(Note4)

±1%

±1%

±1%

±1%

Load stability(Note5)

±1%

±1%

±1%

±1%

DC output power

25W

42W

42W

48W

Efficiency

72%

77%

77%

80%

Adjustable range for DC voltage

4.75-5.5V

10.8-13.2V

13.5-16.5V

21.6-26.4V

AC input voltage range

85264VAC/4763HZ;120370VDC

Input current

1.5A/115V 0.75A/230V

AC impulse current

Cold-start current 30A/115V 60A/230V

Leakage current

<1mA/240VAC

Overload protection

105%150% TypePULSING HICCUP SHUTDOWN Reset. auto recovery

Over-voltage protection

5.75-6.75V/13.8-16.2V/17.25-20.25V/27.6-32.4V

High-temperature protection

……

Temperature coefficient

±0.03%(050)

Setup rise hold up time

800ms,60ms,50ms/230VAC

Vibration

10500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval3KVACInput and enclosure1.5KVACOutput and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure500VAC/100M Ohms

Working temperature and humidity

-10+5020%90%RH

Store temperature and humidity

-20+85,10%95RH

Overall dimension

93*78*67mm

Weight

0.31Kgs 48PCS/14.8KG/1.3CUFT

Safety standards

Meet UL1012

EMC standards

Meet FCC Part 15J Conduction Class B

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.

SendMessage