You are here: Home >> Industries & Products >> Switching Power Supply >> D series >> D-50 Switching Power Supply
86-577-61989999 86-577-61891122 cncele@cncele.com cncelegroup@hotmail.com CNC.ELE.GROUP
D-50 Switching Power Supply
D-50 Switching Power Supply
bookmark this page Bookmark This Page
live messenger Live Messenger
skype me Skype Me
e-mail us cncele@cncele.com
Send Inquiry Send Inquiry
catalogue download Catalogue Download


Product Description: 

Model /Specification

D-50A

D-50B

CH1

CH2

CH1

CH2

DC output voltage

5V

12V

5V

24V

Output voltage error (Note2)

±2%

±5,-8%

±2%

±8%

Rated output current

6A

2A

6A

1A

Output current rage

1-6A

0.3-2A

1-6A

0.2-1A

Wave and noise(Note3)

50mVp-p

100mVp-p

50mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±1%

±0.5%

±1%

Load stability(Note5)

±0.5%

±0.5%

±0.5%

±8%

DC output power

54W

54W

Efficiency

73%

73%

Adjustable range for DC voltage

CH1+10,-5%

CH1+10,-5%

AC input voltage range

85132VAC/170264VAC;selected by switch 4763Hz;240-370VDC

Input current

1.3A/115V 0.65A/230V

AC impulse current

Cold-start current 18A/115V 36A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%150% TypeFOLDBACK Cut off output Reset. auto recovery

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

±0.03%(050) ON+5V OUTPUT

Setup rise hold up time

200ms,50ms,30ms

Vibration

10500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval1.5KVACInput and enclosure1.5KVACOutput and enclosure0.5KVAC

Isolation resistance

Input and output intervalInput and enclosureOutput and enclosure0500VAC/100M Ohms

Working temperature and humidity

-10+6020%90%RH

Store temperature and humidity

-20+85,10%95RH

Overall dimension

159*97*38mm

Weight

0.52Kgs

Safety standards

Meet UL1012

EMC standards

……

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.
6.C2311must be knocked down.

SendMessage